Quick Start Instructions


 

V2.0 & 3.0:

 

Launch the “A664_ProView.exe” executable.
Press F2 to bring up the configuration page. This page allows selection of playback or live mode as
well as specification of the following files:
  • Configuration file – Required file providing which ARINC 664 parameters to process and display.
  • Comma-Separated Value (CSV) file – Optional output file in live or playback mode which will contain decoded ARINC 664 parameter values for all displayed parameters at specified time increments.
  • Recording file – Optional output file in live mode which records ALL live ARINC 664 data.
  • Playback file – Required input file for playback mode. This file must have been created during a previous run of the ProView software or on an ICS Linux-based FTSIU.
Click OK to apply the settings and exit the configuration page.
Click the Run button or press F9 to begin processing of ARINC 664 data.
During playback, the speed can be adjusted by pressing F4 and moving the slider bar to the desired
playback speed. Selection of continuous playback mode can also be controlled through this pop-up
window.

V1.0:

Playback Mode:

  • Launch the “ARINC 664 ProView” application.  There is a shortcut on your Desktop after installation.  There is also an ARINC 664 ProView folder in the Start Menu.
  • Press F2 to load a configuration file previously generated by the ARINC 664 Configuration Tool. Note that the ARINC 664 Configuration Tool can be launched at any time by pressing F12.
  • Press F3 to specify a playback file. This file must have been previously recorded using either the ProView software or on an ICS Linux-based FTSIU platform.
  • Optionally modify the IRIG Start Time by going to Configure->Playback->Modify IIRG Start Time. This will cause the ProView software to skip from the beginning of the playback file up to the specified IRIG Start Time during playback. Note that this field is initially populated with the first IRIG time found in the specified playback file. Leaving this field unmodified will result in the entire file being played back.
  • Optionally check or uncheck (default) the option for continuous playback mode by going to Configure->Playback->Continuous Playback. This option may be changed at any time, including during playback.  Note that during continuous playback mode, the beginning of the file up to the IRIG Start Time will still be skipped on each playback loop, assuming the IRIG Start Time has been modified from its default value.
  • Optionally enable the CSV output by pressing F7 and specifying the desired CSV output file.
  • Begin playback by pressing F9 or clicking on the “Run” button. During playback, the speed can be adjusted by pressing F4 and moving the slider bar to the desired playback speed.
 

Live/Record Mode:

  • Launch the “ARINC 664 ProView” application.  There is a shortcut on your Desktop after installation.  There is also an AARINC 664 ProView folder in the Start Menu.
  • Press F2 to load a configuration file previously generated by the ARINC 664 Configuration Tool. Note that the ARINC 664 Configuration Tool can be launched at any time by pressing F12.
  • Press F5 to select the local Ethernet interface which is connected to the ARINC 664 bus. The drop-down list will be populated with all local Ethernet interfaces which have a valid assigned IP address. If an interface is configure for DHCP and has not been assigned an IP address, it must be assigned a static IP address in order to show up in the list.
  • Optionally choose a recording file by pressing F6. Once a valid recording file is specified, this will automatically enable the ProView software for recording.
  • Optionally enable the CSV output by pressing F7 and specifying the desired CSV output file.
  • Begin live decoding and/or recording of theARINC 664 bus by pressing F9 or clicking on the “Run” button.